MM200 High-Speed Microwave Modem Appendix B
TM086Rev 4.1 B-29
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the MM200 Rx interface volatile table."
::= { radMM200RxInterfaceStatusEntry 1 }
radMM200RxInterfaceMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Interface test
Bit 1-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200RxInterfaceStatusEntry 2 }
radMM200RxInterfaceMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = Interface PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spare
0 = Pass, 1 = Fail"
::= { radMM200RxInterfaceStatusEntry 3 }
radMM200RxInterfaceLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Major Alarm status:
Bit 0 = Interface test
Bit 1-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200RxInterfaceStatusEntry 4 }
radMM200RxInterfaceLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spare
0 = Pass, 1 = Fail"
::= { radMM200RxInterfaceStatusEntry 5 }
radMM200RxInterfaceCard OBJECT-TYPE
SYNTAX INTEGER {
none(1),
asi_aasi(2),
nasi(3),