Appendix A MM200 High-Speed Microwave Modem
A-24 TM086Rev. 4.1
<1>
<1>
<4>
APC Control
APC Hysteresis
APC Level
Sets the APC receive control (Not Yet Implemented)
Sets the APC receive hysteresis level (Not Yet Implemented)
Sets the APC receive level in dBm (Not Yet Implemented)
Status Bytes
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
Major Alarm1
Status
Major Alarm2
Status
Minor Alarm1
Status
Minor Alarm2
Status
Common Alarm1
Status
Common Alarm2
Status
Latched Major
Alarm1 Status
Latched Major
Alarm2 Status
Latched Minor
Alarm1 Status
Latched Minor
Alarm2 Status
Latched Common
Alarm1 Status
Latched
Common Alarm2
0 = Pass, 1 = Fail
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bit 2 = Signal Lock Detect
Bit 3 = Sync Lock Detect
Bit 4 = Deframer clock PLL lock detect
Bit 5 = Diversity FPGA fail
Bits 6 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bits 2 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bit 2 = Signal Lock Detect
Bit 3 = Sync Lock Detect
Bit 4 = Deframer clock PLL lock detect
Bit 5 = Diversity FPGA fail
Bits 6 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bits 2 7 = Spare
0 = Pass, 1 = Fail
Bits 0 7 = Spare