Radyne MM200 Informações Técnicas Página 152

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 151
Appendix B MM200 High-Speed Microwave Modem
B-4 TM086 Rev. 4.1
DESCRIPTION
"Inverts the direction of rotation for the modulation."
::= { radMM200ModNVStatus 12 }
radMM200TxCarrierMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
cw(2),
offset1hz(3),
khz100(4),
mhz35(5),
sweepUp(6),
sweepDown(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal sets the carrier to normal
CW causes the modulator to output pure carrier
Offset 1Hz
100 KHz
3.5 MHz
Sweep up
Sweep down"
::= { radMM200ModNVStatus 13 }
radMM200TxChannelSetting OBJECT-TYPE
SYNTAX INTEGER {
oneChannel(2),
twoChannel(3),
threeChannel(4),
fourChannel(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the total number of channels in the MM200.
Automatic selection allows the MM200 to use the
maximum number of channels."
::= { radMM200ModNVStatus 14 }
radMM200TxMajorAlarm1Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Major Alarm 1 mask:
Bit 0 = Glue logic FPGA fail
Bit 1 = Data FPGA fail
Bit 2-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 15 }
radMM200TxMajorAlarm2Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Major Alarm 2 mask:
Bit 0-7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 16 }
radMM200TxMinorAlarm1Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-write
STATUS current
Vista de página 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 191 192

Comentários a estes Manuais

Sem comentários