Radyne DM240XR Especificações Página 194

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 193
DM240XR High-Speed Digital Modulator AutoEQ™ Interface Operation Guide
MN-DM240XRRevision 13 D–14
D.12 Additional Features
D.12.1 AutoEQ™ Status Indicator
The LED on the back of the AutoEQ interface card can provide additional status for the
operation of the AutoEQ system.
Short Blink Green
Heartbeat, board ready for operation.
Solid Green AutoEQ™ test pattern lock.
Solid Yellow AutoEQ™ data being accessed.
Blink Red AutoEQ™ test pattern unlocked. Signal error.
D.12.2 LNB Power Connector
On the back of the AutoEQ™ interface card is the connector J13 that can be used to insert LNB
power to the J12 SMA connector to feed DC to the LNB.
Mating Connector: PP3-002A 5.5mm x 2.1mm x 9.5mm In-Line DC Power Plug.
(www.cui.com)
Vista de página 193
1 2 ... 189 190 191 192 193 194 195 196

Comentários a estes Manuais

Sem comentários