radQAM256TxMinorAlarm2Mask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Minor alarm 2 mask:
Bits 0..7 = spares
0=mask, 1=allow"
::= { radQAM256ModNVStatus 18 }
radQAM256CommonAlarm1Mask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Common alarm 1 mask:
Bit 0 = Interface hardware fault mask
Bit 1 = M&C hardware fault mask
Bits 2..7 = spares
0=mask, 1=allow"
::= { radQAM256ModNVStatus 19 }
radQAM256CommonAlarm2Mask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Common alarm 2 mask:
Bits 0..7 = spares
0=mask, 1= allow"
::= { radQAM256ModNVStatus 20 }
radQAM256TxControlMode OBJECT-TYPE
SYNTAX INTEGER { local(1), terminal(2), computer(3), ethernet(4) }
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx control mode."
::= { radQAM256ModNVStatus 21 }
radQAM256TxTerrestrialLoopback OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2) }
ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables Tx Terrestrial Loopback."
::= { radQAM256ModNVStatus 22 }
radQAM256TxBasebandLoopback OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2) }
ACCESS read-write
STATUS current
DESCRIPTION
" Enables or disables Tx Baseband Loopback."
::= { radQAM256ModNVStatus 23 }
radQAM256PRBS OBJECT-TYPE
SYNTAX INTEGER { normal(1), prbs23(2), prbs23m(3), prbs15(4),
prbs15m(5) }
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the pseudo-random bit sequence for link testing."
::= { radQAM256ModNVStatus 24 }
radQAM256TxLastRateControl OBJECT-TYPE